adaptor brass cond 3/4in./20mm

Cable Management Machined Brass, 3/4 Inch Male To 20Mm Female Brass Adaptor

Catalogue Number: 1235/20
adaptor brass cond 3/4in./20mm
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Material
brass
Connector type
thread connector
Product destination
diameter: 20-20 mm tube
Length
35-35 mm
Standards
  • AS 1722.2
  • AS 1721
  • ASC 66.1
  • AS 2052
    • REACh Regulation
      Free of Substances of Very High Concern above the threshold
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Installation Instruction

      • Specifications

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      What is part number for lid to suit 1239/20/4?

      Part number 1239L20 will suit any of 1239/20 series.

      What is the thread type on a 1235/25?

      The thread type on a 1235/25 is BS - British Standard.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=1235/25 

      Whati s pitch thread for part number 1245/25?

      Pitch thread is 1.5mm

      What is the part code for the cord connector to suit the PDL56P320F?

      We do not do one this size and with flat pins in 56 series
      clipsal option (not IP rated)
      438/20-WE - extention socket 20A
      1439/20 - 20A plug
       

      Is part number C2015/20 available in Red?

      Yes it is and the part number is C2015/20-RD.

      Does the 1240/25 series come with gaskets?

      No, they are light duty. Buy the 1240HL25 to obtain a heavy duty lid and gasket , or if gasket is required for retro fit then buy 1240GT
      For more information on this product range please visit the Clipsal web site on the link provided
      https://www.clipsal.com/Trade/search-results?q=1240

      Is there a 32A version of the 1439/20?

      No, 20A is the largest size in this model plug.

      What is the cover for a C2015/20?

      The cover for a C2015/20 is a C2015/20C.

      What is the part number for a 20mm steel conduit plug?

      The part number  for a 20mm brass plug for steel conduit is 1220S20.

      What is the difference between the Quantum 140CPS11410 power supply and 140CPS11420 power supply?

      Issue
      Difference between 140CPS11410 and 140CPS11420

      Product Line
      Modicon Quantum

      Resolution
      The Quantum 140CPS11410 is a 115/230 Vac, 8A summable power supply.
      The Quantum 140CPS11420 is a 115/230 Vac, 11A summable power supply.

       

      What is part number for Stainless Steel cover to suit C2015/20?

      The part number for Stainless Steel cover to suit is a C2015/20C.

      Can a three pole breaker be used on a single phase (two-wire) load in a three phase panel?

      Issue:
      Product design

      Product Line:
      Molded Case Circuit Breakers

      Environment:  
      Square D Circuit Breakers

      Cause:
      Application

      Resolution:
      Yes.  According the UL White Book (Product Category DIVQ), multipole common trip circuit breakers rated 125/250V are suitable for use for a single-phase multiwire circuit, with or without the neutral connected to the load.  Courtesy of Mike Holt Enterprises 2008

      Do Clipsal make a 3 pin, 20 amp, switched outlet with flat pins?

      Yes, 20A 3 flat pin switched outlets are available in a few variants , most commonly the 2015/20, C2015/20 and 56C320F.

      For further information please visit:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=2015/20
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015/20
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=56C320F

       

      How do I hardwire 10kva and 20kva transformers in a 208/120 or 240/120 environment

      Issue:
      Implementing a hardwire stepdown transformer in a 208v or 240v environment


      Product Line:

      Smart-UPS / Symmetra

      Environment:

      APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers

      Cause:

      Unbalanced UPS outputs require a stepdown transformer to power 120v loads


      Resolution:

      This document refers to installing  the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual.

      The wiring block outputs are as follows:


      For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position.

      The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal  7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power.



       Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.

      Conext SW - Installation/ Wiring issue.

      Issue:

      Customer is installing the Conext SW and wants to confirm the wiring of the AC and DC cabling. 

      Environment:

      Conext SW 2524 120/240 Split-phase (865-2524)
       
      Conext SW 4024 120/240 Split-phase (865-4024)


      Resolution:
       

      See the attached wiring diagrams for the Conext SW and Conext SW-NA.
      Do not mix AC and DC wiring in the same conduit or panel. Consult the applicable installation code for details.
      There are two dual 3/4" /1" trade-size knockouts on the side panel and another two on the bottom panel for AC wiring. Use the same trade size of strain relief as the trade size of the knockout(s) you are using.

       

      What's the difference between the SyMax Model 50 programmable controllers 8005CP50 and 8005CP51?

      The difference between the two SyMax Model 50 programmable controllers is the power voltage rating.
      8005CP50 is a 120/240 VAC Processor Unit.
      8005CP51 is a 24 VDC Processor Unit.


      Legacy KB System (APS) Data: RESL169642 V1.0, Originally authored by on , Last Edited by on
      Related ranges: Sy/Max

      Do the Advantys STB Power distribution modules (PDT) require an Input Power connection (Sensor Bus) for the island to function properly ?

      Title

      Input power required on a PDT module.

      Issue

       

      Product Line

      Advantys STB

      Environment

       

      Cause

       

      Resolution

      With the 24 Vdc Power distribution module (STBPDT3100), you are required to have this connection, otherwise you will receive a module error (Flashing ERR led) on all 24 Vdc input modules. With the 115/230 Vac Power distribution module (STBPDT2100), you are not required to have this connection, therefore allowing you to connect directly from the field device to the input module.

      Control power rating on the CM4000 series meter is different than what is stated in the specifications in CM4 manual

      Issue
      Control power rating is different than what is shown in the CM4000 series user manual 

      Product Line
      CM4000 Series

      Environment
      Wiring

      Resolution
      The control power for the CM4000 series Circuit Monitors is rated for a voltage range of 90-305V ac or 100-300V dc. It was our standard practice to publish these ratings. Recently a change was implemented to mark the circuit monitors with the nominal voltage ranges instead of the maximum range. As a result the meters now show a control power voltage range of 100-277 V ac or 125-250 V dc.
      If the customer needs a document with signature for their customer, you can send them the following document from John Straughn below.

      CM4 Power Supply Rating.pdf

       

      What is the replacement AC coil for CAD32 and CAD50 relay?

      Issue:
      Are replacement  AC coil available for CAD32 and CAD50 relay?

      Product Line:
      Tesys Relays

      Environment:
      All Products

      Cause:
      Product selection

      Resolution:
      Volt = coil part number
      12 = LXD1J7
      21 = LXD1Z7
      24 = LXD1B7
      32 = LXD1C7
      36 = LXD1CC7
      42 = LXD1D7
      48 = LXD1E7
      60 = LXD1EE7
      100 = LXD1K7
      110 = LXD1F7
      115 = LXD1FE7
      120 = LXD1G7
      127 = LXD1FC7
      200 = LXD1L7
      208 = LXD1LL7
      220/230 = LXD1M7
      230 595 21 LXD1P7
      230/240 = LXD1U7
      277 781 30 LXD1W7
      380/400 = LXD1Q7
      400 = LXD1V7
      415 = LXD1N7
      440 = LXD1R7
      480 = LXD1T7
      600 = LXD1X7
      690 = LXD1Y7

       

      Can the PowerLogic Energy Meter be used to monitor multiple loads?

      Issue
      A user would like to totalize multiple loads with an Energy meter.

      Product Line
      Powerlogic Energy Meter

      Environment
      Energy Meter Installation

      Cause
      The installation guide for the Energy meter does not contain instructions on wiring the meter to monitor multiple loads.

      Resolution
      *Warning: Installation and maintenance of this device should only be performed by qualified, competent personnel that have appropriate training and experience with high voltage and current devices. Failure to follow the instructions / warnings in the Meter Installation Guide can result in permanent damage to the meter, severe injury or death. 

      The Energy meter is calibrated with the set of CTs that are included with the meter, however the Energy Meter can be installed with up to three sets of parallel CTs to monitor multiple loads. When wiring multiple current transformers in parallel to the Energy Meter, all voltages corresponding to the individual loads must be the same voltage values and must be from the same source. The voltage applied to the inputs of the Energy Meter will be used in the power calculations. Monitoring different voltage values and monitoring the same voltage values from different sources will both cause the power calculations to be inaccurate.

      For example, if load A has a system voltage type of 120/208 VAC, and load B has a system voltage type of 277/480 VAC, an Energy Meter cannot be used to measure both loads in a parallel configuration. Likewise, if Load A and Load B both have a system voltage type of 120/208 VAC, but are supplied their respective voltage from different transformers, an Energy Meter cannot be used to measure both loads in a parallel configuration.

      Note: When multiple sets of CTs are connected in parallel to the Energy Meter, the accuracy drops from less than 1% to between 1%-3%.


      Please follow the guidelines in the attached addendum for selecting and installing the parallel CTs on an Energy meter.

      Changing the Language of the Symmetra PowerView RM Display


      Issue

      I need to change the language displayed by my PowerView RM display interface


      Product Line

      Symmetra Power Array
      Symmetra RM
      Symmetra LX
      Symmetra PX
      Smart-UPS VT
      Smart-UPS RT 15/20 kVA
      PowerView display interface


      Environment

      All serial ranges


      Cause

      The display defaults to using the English language.  The user may opt to display the information in a different language.


      Resolution

      You can change the language by downloading new firmware into the PowerView RM interface. French, German, Italian, and Spanish are available on the enclosed CD. Support for additional languages may be available on the CD or at the APC Web site (https://www.apc.com). Product documentation in these languages also appears on the CD or at the APC Web site.  To change the language of the interface, perform the following steps in the order given.


      1. Disconnect the PowerView RM from the UPS.

      2. Disconnect the data cable from the RJ-45 port of the PowerView RM.

      3. Connect the programming cable (included, APC part number 940-0082) between PowerView RM and the UPS data cable:
      a. Attach the RJ-45 connector to the port on the rear of the PowerView RM interface.
      b. Connect the female DB-9 connector of the programming cable to a serial port on the computer. The downloading computer must have access either to the file on the CD provided with PowerView RM or to the APC Web site.
      c. Attach the UPS data cable to the female RJ-45 connector on the programming cable.

      4. Locate the language program file to be downloaded into PowerView RM. Each language program file appears on the CD under the folder of its language(Français, Español, etc.) with a .bin extension. Program files for additional language support or code updates may be available on the APC Web site.

      5. Place the PowerView interface in programming mode by pressing simultaneously the three keys on the right (Escape, Help, and Enter) for about three seconds, until the interface emits a long beep. The LCD will display the Programming screen. To leave the Programming screen before starting a file transfer (step 6), press Esc until it beeps (about one second).

      6. Start HyperTerminal or another terminal emulation program on the computer. Set the communication parameters to 8 bits, no parity, no flow control, 1 stop bit, and 19,200 bps. After establishing a connection, use the Xmodem protocol to transfer the language program file from the CD or your download folder to PowerView RM. When the file transfer is complete, the PowerView RM interface will reset itself and display the Startup screen in the new language. If the file transfer fails, the interface will reset itself. Retry the file transfer by repeating steps 5 and 6.

      7. Quit the terminal session. Disconnect the programming cable and reconnect the UPS data cable to the PowerView RM RJ-45 port.

      8. Affix the PowerView RM to the UPS.
       

      Can you hardwire the input/output of the Matrix-UPS?

      Issue:
      Can the input or output of a Matrix UPS be hardwired?

      Product Line:
      Matrix UPS

      Environment:
      All serial ranges

      Cause:
      A user may wish to hardwire the input/output of the UPS rather than use the supplied input power cord.

      Resolution:
      APC offers a hardwire kit to be used with the 120/208 Matrix-UPS product. The part #s for these kits are as follows:

      MXA001: 5kVA Hardwire kit
      MXA002: 3kVA Hardwire kit

      These hardwire kits replace the standard back plate and allows the input and output of the Matrix to be wired directly to their corresponding electrical panels. This kit provides 120V, 208V and 240V on the output. The electrical specifications for both the Matrix 3kVA and Matrix 5kVA UPS systems are as follows:

      Input Over-current Protection
      3kVA: 20 A
      5kVA: 30 A

      Input/Output Wire Size
      3kVA: 12 AWG
      5kVA: 10 AWG


      What is the part number for the 520VPU19200 Hand Held Programmer (HHP) Accessories Kit?

      Issue
      Part number for Hand Held Programmer (HHP)

      Product Line
      Modicon Micro

      Resolution
      The part number for the 520VPU19200 Hand Held Programmer (HHP) Accessories Kit is 520VIA19200.

      The Kit includes the following:
      1) 115/230 Volt universal power supply.
      2) 9 pin D shell adapter.
      3) 25 in D shell adapter.

      Send an e-mail to service.sales@schneider-electric.com for price and availability.

      What values should be set for the potential transformer (PT) primary and secondary values in a CM4000 when connecting the voltage inputs of meters directly to the bus (with fuses)?

      Issue
      A user may want to know the PT primary and secondary values for a CM4000 upon initial setup

      Product Line
      CM4000

      Environment
      Setup

      Cause
      The meter may be set to "No PT" or the PT ratio may be used. 

      Resolution
      When setting the PT ratio, one may select "No PT" for the PT Primary Scale - there is no requirement to set the PT ratio if "NO PT" is chosen.

      The PT Primary and PT Secondary inputs are still available, but they are not used when "No PT" is selected for the PT Pri Scale.
      A user would set the PT ratio to "No PT" when the system voltage used by the load to be metered is the same as the system voltage connected directly to the meter (i.e. direct connect with no potential transformers used).

      The PT ratio needs to be set only when the load is using a different voltage from the meter voltage inputs (i.e. potential transformers are being utilized). Potential transformers are used when the voltage of the electrical system is higher than the rated specifications of the meter voltage inputs. The PT primary and secondary ratio on the meter should match that of the potential transformers in the field.

      Example 1: When metering a 1.2 kV system with a set of PT's that contain a ratio of 1200:120, the PT Primary of the meter should be set to 1200 and the PT Secondary of the meter should be set to 120.
      (Potential transformers are used in this scenario because 1.2 kV exceeds the acceptable voltage input threshold the CM4000 can withstand (1–690 L-L, 400 L-N)

      Example 2: When metering a a 480V L-L system, no PT's are being used. The system voltage is directly connected to the metering inputs. In this scenario, you would set the PT Pri Scale of the meter to "No PT".

      Note: If the meter receives voltage that is the same as the voltage used by the load and "No PT" is NOT selected, then a PT ratio of 1:1 would need to be used and is still acceptable. (i.e.This result can be achieved by setting the PT Ratio to 120:120 or 480:480)

      XW Won't qualify generator.

      Issue:

      XW inverter charger will not qualify AC generator. AC IN light blinks
      AC input qualification, overloading the generator, unable to sustain battery charging and and running loads (multi-tasking)


      Environment:

      XW 4024/4548/6048 with AC generator


      Resolution:

      1) Ensure generator is split phase 120/240, not 120 monophase or 120/208V. Voltage from (L1 to N) and (N to L2) should add up exactly to (L1 to L2) voltage
      3) Recommended, size your generator 2 times the rating of the XW system.
      2) Ensure no neutral to ground bond in Generator
      3) Connect gen output to AC2, not AC1 and open up AC2 parameters in XW advanced settings - ac settings menu
      4) Reduce max charge rate in XW
      5) If Kohler RES series generator, see  Solution 1179

      Cause:

      1) XW can only connect to splt-ph 120/240 unless converted to monophase 
      2) Potential ground loop
      3) AC2 qualification parameter window much wider than AC1
      4) Gen being overloaded by combination of house loads and XW charger.

      Can a circuit breaker be operated at a voltage less than the voltage marked on the breaker?

      Inquiry:
      Is it OK to apply a circuit breaker on a voltage system rated lower than the rating of the breaker?

      Product Line:
      MCB and MCCB circuit breakers

      Cause:
      Circuit breakers are typically marked only with a few standard voltages, while other voltage systems exist.

      Resolution:
      Yes. According to 2011 NEC article  240.83(E), a circuit breaker may be used at voltages equal to or less than its voltage rating. 
      When applied on a system of lower voltage than marked, he interrupting rating is equal to the next highest marked interrupting rating. 
      The only exceptions to application at less than rated voltage are:
      1. QO and HOM -GFI, -EPD, -AFI, -CAFI, and DF circuit breakers must be applied on 120/240 Vac systems only (they need over 100 Vac to power the electronic modules)
      2. EHB-EPD and EDB-EPD type breakers which must be applied on 480Y/277 systems only

      NOTE:  Circuit breakers marked with DC ratings only are not suitable for application on AC systems, and circuit breakers marked with AC ratings only are not suitable for application on DC systems.

      What is the part number for a Contactor with Low consumption?

      The part number for a low consumption contactor is LC1D09.
      General Product information:
      Range of product TeSys D
      Product or component type Contactor
      Device short name LC1D
      Contactor application Motor control Resistive load
      Utilisation category AC-1, AC-3
      Poles description 3P
      Power pole contact composition 3 NO
      [Ue] rated operational voltage <= 300 V DC for power circuit
      <= 690 V AC 25...400 Hz for power circuit
      [Ie] rated operational current 9 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
      25 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
      Motor power kW 5.5 kW at 660...690 V AC 50/60 Hz
      5.5 kW at 500 V AC 50/60 Hz
      4 kW at 415...440 V AC 50/60 Hz
      4 kW at 380...400 V AC 50/60 Hz
      2.2 kW at 220...230 V AC 50/60 Hz
      Motor power HP (UL / CSA) 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
      5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
      2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
      2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
      1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
      0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
      Control circuit type AC 50/60 Hz
      Control circuit voltage 415 V AC 50/60 Hz
      Auxiliary contact composition 1 NO + 1 NC
      [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
      Overvoltage category III
      [Ith] conventional free air thermal current 10 A at <= 60 °C for signalling circuit
      25 A at <= 60 °C for power circuit



      For more information please visit https://www.schneider-electric.com.au/en/productcontaLC1D



      Lost Neutral - effects on loads and UL1449

      Issue:

      Lost Neutral - effects on loads and UL1449

      Product Line:

      All Back-UPS, Back-UPS PRO and Personal Surge

      Environment:

      Lost Neutral in electrical infrastructure.

      Cause:

      Lifted neutral at utility panel.

      Resolution:

      In a typical balanced load with all loads using the neutral return and the neutral is severed, the voltage from each Phase appears across each load and is added on itself. This is a typical fault condition. Underwriter's Laboratories realized that this fault condition is common and it is not up to the Surge Protection Industry to prevent these failures but in the event of this common failure, UL addressed this condition by requiring all Surge Protectors to pass a fault of 240 VAC at different current levels to simulate different loads. These currents are: 125 mA rms. 500 mA rms. 2.5 A rms. and 5 A rms. They also require an unlimited current test (1000 A rms. or greater). 240 VAC is used because most household wiring is 120/240 3 wire single phase and a lost neutral produces 240 VAC. The unit during this test has cheesecloth wrapped around it. The unit may not emit flame nor can it char the cheesecloth nor can it create an opening in the housing that exposes live metal parts large enough for a child's finger to be inserted. After the test, the unit may not allow leakage currents of > 0.5 mA from Line to Ground and Neutral to Ground also it must withstand a dielectric voltage of 240 VAC for minute between each protected mode. Our units have passed this stringent test requirement in order to get UL recognition and to insure the safety of our customer's lives and property.
       

      What is the dimension of 1264/2M, 25mm (male) to 20mm (female) brass reducer?

      Dimensions of 1264/2M are as follows:
      A = 25mm
      B = 21mm
      C = 16mm


      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=1264/2M

      Can a 3-pole breaker be used in a 2-pole application?

      Issue:
      Can a three pole breaker be used in either a two pole or a single phase application?

      Product Line:
      MCCB

      Environment:
      Powerpact and Masterpact

      Resolution:
      • A 3p breaker can be used on a 3 phase system using either 2 or 3 poles.
      • A 3p breaker can be used on a 1 phase system only if indicated by the markings as noted below.
      For reference:
      • Per NEC article 240.85: "A circuit breaker with a straight voltage rating, such as 240V or 480V, shall be permitted to be applied in a circuit in which the nominal voltage between any two conductors does not exceed the circuit breaker’s voltage rating."
      • According to UL's White book, "3–pole circuit breakers are suitable for use on 3-phase systems only, unless marked to indicate use on 1-phase systems, such as, “For 1–phase connections, use two outside poles,” or an equivalent statement. A 3-pole breaker used in place of a 2-pole breaker on a 3-phase system, such as a 2-pole breaker used in a branch circuit that is actually two legs of a 3-phase system, is acceptable without the 3-pole breaker being specifically marked."

      Powerpact P
      • The 3-pole P-frame breaker has a marking on the cover that states "single phase any 2 poles". Therefore on a 120/240Vac system, it is ok to use any 2 poles of a 3 pole P-frame breaker.
      • This breaker marking correlates with the wiring diagram markings of the M and P breaker enclosure, which shows both 2p and 3p applications.
      Powerpact L
      • The 3-pole L-frame breaker does NOT have a marking for single phase systems. Therefore on the 120/240Vac system, it is NOT ok to use a 3 pole L-frame breaker.
      • This marking correlates with the wiring diagram of the L breaker enclosure, which shows only 3p applications.
      Powerpact H and J
      • Three-pole Powerpact H and J-frame thermal-magnetic breakers are marked for single phase use
      • Three-pole Powerpact H and J-frame Micrologic breakers with standard trip units (U31X and U33X) are marked for single-phase use
      • Three-pole Powerpact H and J-frame Micrologic breakers with Ammeter and Energy trip units (U43X, U44X, U53X and U54X) are NOT marked for single-phase use.

      Energy Meter shows "Phase Loss" Alarm

      Issue
      Energy meter shows “Phase Loss” alarm on front display.

      Product Line
      Energy meter (EMB and EME series).

      Environment
      Installing/wiring energy meter

      Cause
      If the voltage of any phase is measured as less than 75% of the voltage on any other phase, the display will show PHASE LOSS and indicate the specific phase(s).

      Resolution
      If the energy meter is installed with the proper number of phases (see selection below to determine this) then the phase voltages should be verified. If the number of phases installed is not correct, then the phase loss alarm will be indicated in all operating conditions.

      It’s very important to know the model number of your Energy meter.  
      For example, users see “Phase Loss” error when they use EMB2043 (1 phase, 3 wire) with 1 phase, 2 wire application.

      As a result, it’s very important for users to know their application and use appropriate meter that meets their system type.  Please review the tables below for selecting correct meter.

      Basic 120/240 Volt 208 Wye

      EMB1010 Basic 100A 1 Phase, 2 wire installation 1 CT
      EMB1021 Basic 200A 1 Phase, 2 wire installation 1 CT
      EMB1032 Basic 300A 1 Phase, 2 wire installation 1 CT
      EMB2010 Basic 100A 1 Phase, 3 wire installation 2 CTs
      EMB2021 Basic 200A 1 Phase, 3 wire installation 2 CTs
      EMB2032 Basic 300A 1 Phase, 3 wire installation 2 CTs
      EMB2043 Basic 400A 1 Phase, 3 wire installation 2 CTs
      EMB2083 Basic 800A 1 Phase, 3 wire installation 2 CTs
      EMB3010 Basic 100A 3 Phase, 4 wire installation 3 CTs
      EMB3021 Basic 200A 3 Phase, 4 wire installation 3 CTs
      EMB3032 Basic 300A 3 Phase, 4 wire installation 3 CTs
      EMB3043 Basic 400A 3 Phase, 4 wire installation 3 CTs
      EMB3083 Basic 800A 3 Phase, 4 wire installation 3 CTs
      EMB3084 Basic 800A 3 Phase, 4 wire installation 3 CTs
      EMB3164 Basic 1600A 3 Phase, 4 wire installation 3 CTs


      Extended Range 120/480 Volt Wye

      EME1010 Basic 100A 1 Phase, 2 wire installation 1 CT
      EME1021 Basic 200A 1 Phase, 2 wire installation 1 CT
      EME1032 Basic 300A 1 Phase, 2 wire installation 1 CT
      EME2010 Basic 100A 1 Phase, 3 wire installation 2 CTs
      EME2021 Basic 200A 1 Phase, 3 wire installation 2 CTs
      EME2032 Basic 300A 1 Phase, 3 wire installation 2 CTs
      EME2043 Basic 400A 1 Phase, 3 wire installation 2 CTs
      EME2083 Basic 800A 1 Phase, 3 wire installation 2 CTs
      EME3010 Basic 100A 3 Phase, 4 wire installation 3 CTs
      EME3021 Basic 200A 3 Phase, 4 wire installation 3 CTs
      EME3032 Basic 300A 3 Phase, 4 wire installation 3 CTs
      EME3043 Basic 400A 3 Phase, 4 wire installation 3 CTs
      EME3083 Basic 800A 3 Phase, 4 wire installation 3 CTs
      EME3084 Basic 800A 3 Phase, 4 wire installation 3 CTs
      EME3164 Basic 1600A 3 Phase, 4 wire installation 3 CTs


      NOTE: the meter will operate, however the phase loss alarm will constantly be present if the improper meter is in use.

      Where can I get support for APC and MGE Products?

      For support on APC and MGE products please visit:  https://www.apc.com/support/

      AC Power
      Additional Management Cards and Options
      Air Cooled Chillers
      Air Distribution Accessories
      Airflow Management
      AIS 3000
      AIS 5000
      AIS Accessories
      AIS Battery Systems
      APC CS
      APC Enterprise Manager
      APC ES
      APC RS
      Application Shutdown Utilities
      Assessment Services
      Auto and Air Inverters
      AV Accessories
      AV Power Conditioners & Battery Backups
      AV Power Filters
      AV Pro Interconnects
      AV Surge Protectors
      Backpacks and Messenger Bags
      Back-UPS
      Back-UPS Accessories
      Back-UPS BI
      Back-UPS CS
      Back-UPS ES
      Back-UPS HI
      Back-UPS HT
      Back-UPS LS
      Back-UPS Office
      Back-UPS Pro
      Back-UPS RS
      Back-UPS XS
      Basic Rack PDU
      Battery Management
      Battery Replacement Services
      Biometric Security
      Bulk Cable
      Cabinet Power Distribution
      Cable Management
      Charge-UPS EX
      Commercial/Industrial Surge Suppression
      Condensers
      Configurable Power Accessories
      Configurable Power Distribution
      Console Port Servers
      CyberFort
      Data Center Facility Cooling - Andover Continuum or TAC Vista
      Data Center Facility Power - PowerLogic ION Enterprise
      Data Center Software Integration Kits
      Data Center University
      Data Distribution Cable
      DC Battery
      DC Components
      DC Distribution Components
      DC600
      Desktop KVM
      Desktop Notebook Stands
      EcoBreeze Air Economizers
      Environmental Management System
      Environmental Monitoring Unit
      Ethernet Switches
      Extended Warranties
      Fiber Optics
      Firmware Upgrades
      FLM Series
      Fluid Coolers
      FRP/Ferroresonant Power Supply
      Game Console Surge Protection
      Gender Changers
      Global Deployment
      Hardwire Surge Suppression Accessories
      High-Density Cooling Enclosures
      IDE Cables
      IEEE1394
      Industrial
      InfraStruxure for Large Data Centers
      InfraStruxure for Medium Data Centers
      InfraStruxure for Server Rooms
      InfraStruxure for Small Data Centers
      InfraStruxure for Wiring Closets
      InfraStruxure Manager
      InfraStruxure Type A
      InRoom Direct Expansion
      InRow Chilled Water
      InRow Direct Expansion
      InRow Pumped Refrigerant
      Installation Services
      Interface Cables
      International Plug Adapters
      Keyboard
      KVM Switches
      Laptop Power Adapters
      Line-R
      Magnum VS
      Magnum XS
      Magnum XS Rectifier
      Maintenance Bypass Panels
      Management Platform Integration
      Matrix Battery Systems
      Matrix-UPS
      Matrix-UPS Accessories
      Metered Rack PDU
      Metered-by-Outlet Rack PDU
      MGE Accessories
      MGE Alpes
      MGE Battery Systems
      MGE Comet
      MGE EPS
      MGE EPS 6000
      MGE EPS 7000
      MGE EPS 8000
      MGE Galaxy
      MGE Galaxy 300
      MGE Galaxy 3000
      MGE Galaxy 3500
      MGE Galaxy 4000
      MGE Galaxy 5000
      MGE Galaxy 5500
      MGE Galaxy 6000
      MGE Galaxy 7000
      MGE Galaxy 9000
      MGE Galaxy PW
      MGE Legacy
      MGE Service Bypass
      MGE Sinewave
      MGE Static Transfer Switches
      MGE UPS 4000
      Microsol Estabilizadores
      Microsol Modules Isoladores
      Mobile Notebook Stands
      Modular Components
      Modular Power Accessories
      Modular Power Distribution
      Monitor
      Mounting Hardware
      Mouse
      MRC1800
      MRE2400
      Multimedia
      MWF1700
      NetBotz 200
      NetBotz 300
      NetBotz 400
      NetBotz 500
      NetBotz Access Control
      NetBotz Accessories and Cables
      NetBotz Central
      NetBotz Rack Access
      NetBotz Sensors
      NetShelter CX
      NetShelter EP Enclosures
      NetShelter ES Enclosures
      NetShelter Open Frame Rack Accessories
      NetShelter SX
      NetShelter VL
      NetShelter VS Enclosures
      NetShelter VX Enclosures
      Network Integration Services
      Network Patch Cables
      NetworkAIR Accessories
      NetworkAIR AFX
      NetworkAIR CM
      NetworkAIR CW
      NetworkAIR FM
      NetworkAIR IR
      NetworkAIR TC
      Notebook Security
      On Site Service
      Open Frame Racks
      Operations Capacity
      Operations Change
      Operations Energy Cost
      Operations Energy Efficiency
      Operations Insight
      Operations Mobile
      Operations VIZOR
      Outdoor Enclosures
      Panelmount Environmental Monitoring
      Parallel
      Patch Panels
      PC1200
      Planning Tools and Publications
      Portable Cooling
      Power Cords
      Power Distribution Units
      Power Generation Systems
      Power Ready Notebook Cases
      PowerChute Business Edition
      PowerChute Inventory Manager
      PowerChute Network Shutdown
      PowerChute Personal Edition
      PowerChute plus
      PowerManager
      PowerShield
      Preventive Maintenance
      Project Management Services
      ProtectNet
      Rack Air Distribution
      Rack Components
      Rack LCD Consoles
      Rack PDU Accessories
      Rack-mount Transfer Switches
      Refrigerant Distribution
      Remote Monitoring Services
      Replacement Batteries
      Replacement Notebook Batteries
      Residential Hardwire Surge Suppression
      Retail
      Retractable Cables
      Room Air Distribution
      Room Cooling Accessories
      Router Cables
      Row Cooling Accessories
      SCSI
      Security Cameras
      Sensors
      Serial
      Service Bypass Panel
      Service Plans
      Silcon
      Silcon Accessories
      Silcon Battery Systems
      SLM/FLM Series
      SmartSlot Expansion Chassis
      Smart-UPS
      Smart-UPS Accessories
      Smart-UPS Battery Systems
      Smart-UPS DP
      Smart-UPS On-Line
      Smart-UPS RT
      Smart-UPS VT
      Software Configuration
      Software Education
      Software for NetBotz Appliances
      Software Installation
      Software Integration
      Spare Part Kits
      Specialty Enclosures
      Start-Up Service
      Stationary Power Distribution Units
      Step-Down Transformer
      StruxureWare Central
      StruxureWare Operations Suite
      SurgeArrest Essential
      SurgeArrest Home/Office
      SurgeArrest Notebook
      SurgeArrest Performance
      Switch Boxes
      Switched Rack PDU
      Symmetra
      Symmetra Accessories
      Symmetra Battery Systems
      Symmetra MW
      Symmetra MW Accessories
      Symmetra Power Module
      Symmetra PX
      Symmetra PX Accessories
      Sync and Charge Cables
      Thermal Containment
      Thick and Thin Ethernet
      Token Ring
      Toploading Cases
      Traditional Cases
      Training Services
      Transceivers
      Transportation
      Travel Mice
      TSP Accessories
      TSP Battery
      TSP/Generator
      TSP/Total System Power
      Tune-UPS for Symmetra
      Uniflair Chilled Water
      Universal Mobile Device Batteries
      Universal Notebook Batteries
      Universal Notebook Power Adapter
      Universal Power Accessories
      Universal Power Adapters
      UPS Network Hub Card
      UPS Network Management Cards
      USB Adapters & Converters
      USB Cables
      USB Charging Cables
      USB Hubs
      Wall-mount Transfer Switches
      Wheeled Cases
      Wireless
      Wizards and Configurators
      WS200