Quantcast

Socket Auto Switched Single Double Pole 10A with Safety Shutter

White Electric | Socket Auto Switched Single Double Pole 10A with Safety Shutter

Socket Auto Switched Single Double Pole 10A with Safety Shutter

Item Number: 10DS-WE

Retail
$111.03
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Standard Series

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Quantity per set

set of 1

Marking

without marking

Protection type

fingersafe

Local signalling

without light indicator

Fixing mode

by screws

[In] rated current

10 A

[Ue] rated operational voltage

250 V AC

Depth

16 mm

Length

115 mm

Width

73 mm

Fixing center

84 mm

Number of poles

2

Standards

  • AS/NZS 3100
  • AS/NZS 3112
  • AS/NZS 3133:approval number S/1
    • REACh Regulation

      Free of Substances of Very High Concern above the threshold

      EU RoHS Directive

      Compliant

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

      Product out of China RoHS scope. Substance declaration for your information

      Environmental Disclosure

      ENVPEP120506EN

      Others

      Cover type

      full cover plate

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      0.08 kg

      Package 1 Height

      16 mm

      Package 1 width

      73 mm

      Package 1 Length

      115 mm

      Unit Type of Package 2

      BB1

      Number of Units in Package 2

      5

      Package 2 Weight

      0.4 kg

      Package 2 Height

      117 mm

      Package 2 width

      102 mm

      Package 2 Length

      138 mm

      Unit Type of Package 3

      CAR

      Number of Units in Package 3

      50

      Package 3 Weight

      4 kg

      Package 3 Height

      157 mm

      Package 3 width

      305 mm

      Package 3 Length

      445 mm
      Show all specifications

      Documents & downloads

      hide show
      Filter items
      • All

      • Technical Data Catalogues

      Frequently Asked Questions

      hide show

      What is the replacement for a E03/30/10 RCD relay?

      The replacement for a E03/30/10 RCD relay is a E03/10/10. The only difference is the E03/10/10 is 10mA instead of 30mA.
      Some of the key features are:

      • With mounting bracket
      • Suitable for single to three phase applications
      • Amber load supply indicator
      • In-built test facility
      • -10 to +55 deg C Operating Temperature
      • 50-250 Ohms Load Range (shunt trip coil)

      For more information see:https://www.clipsal.com/products/detail?CatNo=E03/10/10&backto=/search?q=E03&tab-document-1=0&itemno=E03/10/10
      rcd relay 10ma 10ms 240v

      HomeSafe - Dimensions of Reed switches

      The below list are all measured in mm - all Reed Switches are Normally Closed with the magnet in place (NC)

      5460               18h x 19w x 13d
      5460FD            19(dia)
      5460FS            9.5(dia)
      5460HD            88h x 38w x 10d (cable lenght: 280)
      5460RF            78h x 73w x 27d

      How to configure ATS22 to test an unloaded motor?

      Issue:
      Can an unloaded motor be tested with an ATS22 Softstarter?

      Product Line:
      Altistart 22

      Environment:
      Shop tests, unloaded motor

      Cause:
      Testing the ATS with an unloaded motor, usually trips the ATS22 with SSCr.

      Resolution:
      Yes.
      After entering the correct motor data, set the following parameters:

      - LAC = ON
       - t90 =  Factory 30 change to 10. ( Due to No Load connected and monitor ramp acceleration. This value to be changed back or increased when in the field under actual start-up )
      - ILt =    Factor 350 change to 200% for Shop Testing. ( Value to be changed in the field if Current Limit trips out )
      - tLS =   Factory 15s change to 60s for Shop Testing. ( Changed back to 15s after completion of testing )
      - ACC = Factory 10s change to 60s for Shop Testing. ( Changed back to 10s after completion of testing )
      - SSC = Factory On, changed to oFF. ( Using Voltage control vs. Torque )
      - ItH =   On. ( Factory is On)

      How is an ATV61 or ATV71 drive configured for a 2 part dual ramp?

      Issue:
      Configuring an ATV61 or ATV71 drive for 2 part dual ramp

      Product Line:
      Altivar 61 and Altivar 71 

      Environment:
      All models, All serial numbers

      Cause:
      Application requires the motor to ramp to a minimum speed in a short amount of time and then ramp from this minimum speed to full speed at a much slower rate.

      Resolution:
      The ATV61 and ATV71 drives have a split ramp function in Menu 1.7APPLICATION FUNCTIONS, Sub-menu RAMP.  Define the acceleration and deceleration in 2 steps, split at a certain output frequency.  The following parameters are involved:

      ACC = Acceleration for the lower part of the ramp.
      DEC = Deceleration for the lower part of the ramp.
      AC2 = Acceleration for the upper part of the ramp.
      DE2 = Deceleration for the upper part of the ramp.
      FRT = Ramp 2 threshold, the speed, in Hz. at which the drive switches between ramp 1 (ACC,DEC) parameters and ramp 2 (AC2,DE2) parameters.

      Example:

      ACC = 10sec
      DEC = 10sec
      AC2 = 60sec
      DE2 = 30sec
      FRT = 30Hz

      When the drive starts the motor with a 60Hz speed reference, it will ramp up from 0Hz to 30Hz in 5sec because ACC = 10s so 0Hz to 30Hz is half of the 10s.  Then, it will ramp up from 30Hz to 60Hz in 30sec because AC2 = 60s.  Total ramp up time is 35sec.   When stopping, it will ramp down from 60Hz to 30Hz in 15sec and then 30Hz to 0Hz in 5sec.  Total ramp down time is 20sec.
      Note that the ACC/AC2 times are defined as time to go from 0Hz to motor rated frequency(FrS) 60Hz.  DEC/DE2 is time to go from FrS to 0Hz.