Automatic Single Switch Socket Outlet 250VAC, 10A, Round Earth PIN, with Shutter

White Electric | Automatic Single Switch Socket Outlet 250VAC, 10A, Round Earth PIN, with Shutter

Automatic Single Switch Socket Outlet 250VAC, 10A, Round Earth PIN, with Shutter

Item Number: 10DLS-WE

Retail
$102.00
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Standard Series

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Quantity per set

set of 1

Marking

without marking

Protection type

fingersafe

Local signalling

without light indicator

Fixing mode

by screws

[In] rated current

10 A

[Ue] rated operational voltage

250 V AC

Depth

16 mm

Length

115 mm

Width

73 mm

Fixing center

84 mm

Standards

  • AS/NZS 3100
  • AS/NZS 3112
  • AS/NZS 3133:approval number S/1
    • EU RoHS Directive

      Compliant

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

      Product out of China RoHS scope. Substance declaration for your information

      Environmental Disclosure

      ENVPEP120506EN

      Others

      Cover type

      full cover plate

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      82 g

      Package 1 Height

      25 mm

      Package 1 width

      70 mm

      Package 1 Length

      115 mm

      Unit Type of Package 2

      BB1

      Number of Units in Package 2

      5

      Package 2 Weight

      0.5 kg

      Package 2 Height

      117 mm

      Package 2 width

      102 mm

      Package 2 Length

      138 mm

      Unit Type of Package 3

      CAR

      Number of Units in Package 3

      50

      Package 3 Weight

      5 kg

      Package 3 Height

      157 mm

      Package 3 width

      305 mm

      Package 3 Length

      445 mm
      Show all specifications

      Frequently Asked Questions

      hide show

      How to enable 100ms Frequency monitoring on a CM4000 series meter

      Issue
      Enabling 100ms frequency monitoring on a CM4000

      Product Line
      CM4000

      Environment
      High Speed Monitoring

      Cause
      By default 100ms frequency monitoring is not enabled

      Resolution
      100ms Frequency monitoring is disabled by default on the CM4000 series meters. To enable this feature, the following command writes must be executed to the meter:

      Write 9020 to register 8000
      Write 11 to register 3239
      Write 1 to register 8001
      Write 9021 to register 8000

      This will enable 100ms Frequency monitoring. The value is stored in register 1080 (Units - 0.01 Hz).

      What is the part number for the Input Simulator for a 10DRF Twido Compact Controller?

      The part number is TWDDXSM6


      Legacy KB System (APS) Data: RESL173962 V1.0, Originally authored by on , Last Edited by on
      Related ranges: Twido

      What is the 15 amp version of the 10DWP?

      The 15 amp version of the 10DWP is the 10DWP15.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=10DWP15

      How can timer values be displayed in 10ths of seconds on Magelis XBT terminals?

      In the Properties of Alphanumeric Fields set the conversion multiplier to 0.1 and change the digits after decimal point to fixed and 1.


      What is the minimum group refresh rate with OFS V3.60?

      The minimum OPC group update rate supported by OFS is 300ms

       

      3720ACM responds to every other request in a modbus network

      Goals and Symptoms

      In a Modbus master-slave network, legacy meter responds only to every other request and ignore the others.

      Causes and Fixes

      In Modbus RTU communication topology, messages start with a silent interval of AT LEAST 3.5 characters. This is most easily implemented as a multiple of character times at the baud rate that is being used on the network. In legacy Power Measurement meters, depending on the network, the silent interval may exceed 3.5 characters. On a healthy network with baud rate 9600 this gap should be equal to ~3ms, which is too fast for the legacy devices to catch. On a newer network like this any message sent will hit the silent interval on the 3720, so the meter will not respond. However, the following request will be received after enough silent duration and the meter will respond. This will carry on so the meter will only respond to every other request.
      Adjusting the RTS (Request To Send) interval greater than 100ms (or longer) on the master side will enable the meter to catch all the request packages sent to the network. This adjustment will manipulate the master to hold 100 ms in between every request which will give enough time to the legacy meters.



      Last Revised: April 10, 2008
      Applies To: 3720 ACM
      Original Author: KG
      Public
      All content © 1992-2008 Schneider Electric


      Legacy KB System (APS) Data: RESL191660 V1.0, Originally authored by KBAdPM on 04/11/2008, Last Edited by KBAdPM on 04/11/2008
      Related ranges: 3720 ACM