socket auto sing dp 15a shutt

Automatic Single Switch Socket Outlet 250VAC, 15A, Safety Shutter, Standard Size

Catalogue Number: 10D15S
socket auto sing dp 15a shutt
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Standard Series
Product brand
Clipsal
Quantity per set
set of 1
Cover type
full cover plate
Marking
without marking
Protection type
fingersafe
Local signalling
without light indicator
Fixing mode
by screws
[In] rated current
15 A
[Ue] rated operational voltage
250 V AC
Depth
16 mm
Length
115 mm
Width
73 mm
Fixing center
84 mm
Standards
  • AS/NZS 3100
  • AS/NZS 3112
  • AS/NZS 3133:approval number S/1
    • EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information

      Frequently Asked Questions

      hide show

      Is it possible to test several 755FM units which are all interconnected?

      Hold the test button down for about 10-15 seconds and other smoke alarms on circuit should go off

      Netbotz Advanced view errors during Installation: “The uninstallation could not complete due to an error.”

      Issue:
      Netbotz Advanced view errors during Installation: “The uninstallation could not complete due to an error.”

      Product Line:
      NetBotz

      Environment:
      NetBotz version 2 Advanced View

      Cause:
      If you receive this error when upgrading Advanced View from a previous version, click OK in the error message box. The installation proceeds normally and appears to complete successfully, but some portions of the previous version of Advanced View are not successfully deleted.

      Resolution:
      To complete the uninstallation of the previous version of Advanced View:

      1. Delete any desktop icons from the previous version of Advanced View.
      2. Delete any Start menu entries for the previous versions of Advanced View
       

      How do i silence my 755PSMA2?

      To silence the 755PSMA you need to press and hold the buttton on the front of the smoke detector for 10-15 seconds not only will it silence the alarm but it will also reset it.
      Some of the key features are:
      • New look design with easy to use test/hush button
      • Easy installation and maintenance
      • Wired interconnect feature (up to 40 alarms)
      • Optional relay or wireless interconnect bases
      • Backwards compatible with 755PSMA and 755SMA mounting bases
      • Robust digital design

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=755PSMA2


      Why wont my 755PSMA2 smoke alarms interconnect?

      To test the interconnect between the smoke alarms you are required to hold the test button for 10-15 seconds. The Smoke alarm you are testing will then pause and you will be able to hear the other alarms start alarming until your finger is released from the test button.

      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=755PSMA2
       

      Can split doors be installed on the front of a NetShelter SX, VX or SV cabinet?

      Issue: 
      It can not be assumed that the rear split doors will install onto the front of the cabinet. Confirmation is needed.  

      Product Line: 
      NetShelter SX, NetShelter VX, NetShelter SV
       
      Environment:
      All versions and serial ranges.
       
      Cause: 
      A customer may want to install split doors onto the front of a NetShelter SX cabinet.
       
      Resolution :

      Rear split doors can be installed onto the front of a NetShelter SX, VX and SV cabinets. 
      A replacement split door kit can be purchased or the existing split rear doors can be swapped to the front of the cabinet.
      The replacement door kit includes all of the necessary hardware, including hinges.
      The NetShelter one-piece front door may also be installed onto the rear of the cabinet. 
       

      ION_Data Maintenance Job Fails

      Goals and Symptoms


      Summary

      The scheduled maintenance job for the ION_Data database fails due to insufficient space on the C drive.

      Symptoms

      The following information appears in the Task History of the Maintenance job for the ION_Data database:

        • Step 1

          Executed as user: NT AUTHORITY\SYSTEM. Insufficient space is available on C: drive to execute the requested task. The system database tempdb must be able to grow to 1085.60 MB to complete the requested task.

           

          Job Outcome

          The job failed.    The Job was invoked by Schedule 11 (Schedule for [ION_Data] - MAINTENANCE - Job).    The last step to run was step 4 (Step 4 - Email On Task Failure).

      Facts and Changes

      KeywordsION_Data

      Maintenance

      Database Manager

      Causes and Fixes

      Cause

      There is insufficient disk space on the C drive.  If the available space is less than 1.1GB, the Maintenance schedule will not work.

      Resolution

      Free up space on the C drive to let the system database (tempdb) to grow to 1.1 GB.

      Alternatively, move tempdb to a location where there is sufficient space.  See KB article 10156 for instructions on how to do this.

       

      Original article#10873


      Legacy KB System (APS) Data: RESL182947 V1.0, Originally authored by DaMi on 03/20/2007, Last Edited by DaMi on 03/20/2007
      Related ranges: ION Enterprise

      Link150 Password Reset

      Issue
      It is not possible to generate the backdoor password of Link150. We have to perform only the factory reset so Link150 will return to the default user name and password.
      Product Line
      Link150

      Cause
      Forgetting the web page password for the Link150

      Resolution
      Module State Indication LED shall flash, GREEN for first 10 seconds, and then RED for 10-15 seconds. 
       
      Actions Effects
      Press and hold the 'reset pin' 1 - 5 seconds     LED: Flashing GREEN
        10 - 15 seconds     LED: Flashing RED: All user-configurable information is reset to factory defaults


      Release the pin when the Module State LED starts flashing RED (i,e 10 - 15 seconds)    Device reboots.
      Factory settings will be applied. The default password can be found at FA299649

      NOTE: 
      •    If the 'reset pin' is released, after 5 seconds and before 10 seconds, no action will be performed, LED will be flashing GREEN, till the 'reset pin' is released.
      •    If the 'reset pin' is released after 15 seconds, no action will be performed, LED will be turned to GREEN. 

      ION over Modbus communications for PM8000 and ION7400 series meters

      Issue
      New features and improvements were made on firmware version v1.4.1 for the PM8000 and ION7400 meters. This attached document (TechnicalBulletin_ION-Modbus_v1.3) addresses issues related to replacing legacy products on a Modbus serial (RS-485) bus connected to PME systems.

      ION over Modbus is a communications method that allows an ION master such as EcoStruxure™ Power Monitoring Expert or PowerLogic™ ION Setup software full access to all the ION modules inside the ION meter, while communicating using Modbus RTU protocol on the serial daisy chain.

      The primary use of ION over Modbus is specifically for retrofit applications, where a Modbus meter such as the PowerLogic PM800 series meter is being replaced by an ION meter such as the PowerLogic PM8000 series meter on the RS-485 serial bus.

      Product Line
      PM8000
      ION7400

      Cause 
      ION masters such as Power Monitoring Expert (PME) and ION Setup use ION protocol to communicate with an ION meter to access and manipulate the ION modules in the meter.  However, if the ION meter is added to a Modbus serial daisy chain, the ION meter must be configured as a Modbus device (i.e., protocol set to Modbus RTU) to allow Modbus masters access to the mapped Modbus registers in the ION meter.
       
      PME and ION Setup use Modbus protocol to communicate with a Modbus gateway and the serial daisy-chained meters.  Historically, an ION meter that has been added as a Modbus RTU device in the Modbus serial daisy chain cannot be easily configured, i.e., PME or ION Setup cannot access the ION modules in the meter because the communications protocol is set to Modbus RTU, not ION. 

      Resolution
      All ION meters support the Modbus RTU protocol. Newer ION meter firmware adds ION over Modbus functionality. This enables an ION master such as Power Monitoring Expert or ION Setup to access all configuration and historical data in the meter while it is connected to a serial communications bus and configured as a Modbus RTU device

      Updates are available for Power Monitoring Expert and ION Setup to support ION over Modbus for communication networks utilizing an Ethernet to serial gateway device to connect to the serial daisy chain.



      Power Monitoring Expert and ION Setup currently do not support ION over Modbus communications for:
      • Direct Ethernet or direct serial communications connections.
      • Serial communications sites that use serial-to-serial communications converters such as an RS 232 to RS 485 converter or USB to RS 485 adapter.
      • Modem sites (telephone, radio or fiber optic).
      Serial communications considerations
      ION meters can generate larger volumes of historical data, events or waveforms, which might cause communications performance issues.  It is recommended not to exceed 10-15 devices wired on the same RS-485 daisy chain.


      Prerequisites
      To use ION over Modbus, both your ION meter and ION software must meet the minimum requirements:
      ION meter
      • PM8000 firmware v1.4.1 or later
      • ION7400 firmware v1.4.1 or later
      ION software
      • Power Monitoring Expert 8.2 CU1  (Cumulative Update #1) or later. This update is available for download from this Box link.
      • The latest version of ION Setup (available from Box at Schneider electric)

      For more information on ION over Modbus Communication, review the attached Technical Bulletin.