Mureva Box 116 x 116 x 62mm, IP55, Halogen Free

Mureva Box 116 x 116 x 62mm, IP55, Halogen Free

Mureva Box 116 x 116 x 62mm, IP55, Halogen Free

Item Number: 05045

Retail
$56.44
RRP (Inc. GST)

Product Dimensions

Width icon

Width115 mm

Height icon

Height115 mm

Depth icon

Depth61 mm

Datasheet

Specifications

Design

Colour code

RAL 7035

Warranty

18 months

Physical

Cable entry

smooth faces

Device mounting

surface

Height

115 mm

Width

115 mm

Depth

61 mm

IP degree of protection

IP55

IK degree of protection

IK07

Ambient air temperature for operation

-5-40 °C

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Others

Box category

medium size junction box

Cover fixing

quarter turn screw

Housing material

polypropylene

Internal height

107 mm

Internal width

107 mm

Internal depth

55 mm

Package 1 Weight

0.136 kg

Package 1 Height

62 mm

Package 1 width

114 mm

Package 1 Length

114 mm
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Technical Data Catalogues

  • Specifications

Frequently Asked Questions

hide show

Why is my drive not storing parameter changes after a power cycle?

Issue:
Parameter changes made to the drive over a network (ModBus, CANopen, etc) reset to default values after a power cycle.

Product Line:
ATV31, ATV312, ATV12, ATV61, ATV71

Environment:
All part numbers.
Adjusments via network

Cause:
Parameter changes are made to RAM and not to EEPROM

Resolution:
Adjustments made over the network are stored to the operating memory (RAM) in the drive so it will be lost after a power cycle.
To have the settings stored to the EEPROM the customer must set Bit 1 of the CMI (Extended control word; address 8504) to 1.
This bit will reset to 0 after a save had been completed.

NOTE: The EEPROM has a limit to the number of times it can be written.  This is 1,000,000 writes for the ATV312.  ATV12, ATV61 and ATV71 are limited to 100,000 writes

How to change the display settings of energy units from MWh to kWh in ME Meter.

Depending on the ME meter version, meter will automatically select the appropriate units and therefore it is not possible to modify the energy units. From 40/5 to 150/5 CT ratio, the energy unit display is KWh and from 200/5 to 6000/5 CT ratio, the energy unit display is MWh.

CT Setting:
To change the CT settings hold down the button on the Front Face of the ME Meter for more than 5 sec when on the CT Rating display. After approximately 5 sec the display will start blinking, now enter the CT setting. Once again hold the button till the display stop flashing, to ensure that the entry is saved.

Where can I find ATV61 programming assistance with the water solutions card VW3A3503?

Issue:  
Programming and wiring up a water solution card on the ATV61 drives?

Product line:
Altivar ATV61 with water solutions option card VW3A3503.

Environment:
All models, all serial numbers 

Cause:
Water Solution Card set up configuration.

Resolution:
First, go through the Pre-Configuration section in the manual.   Transducer is 0-145 PSI with 4-20mA Output. There are 2 additional External pumps.   Go to Page 86 to set System Units =1 (Imp, Gallon and Degree Fahrenheit)   Water Solutions/Expansion/PID PID Ref Local (Local PID reference will appear under Water Solutions menu) PID Max Ref 100 psi PID Feedback  Drive AI2 PID Gain 50 PID Integral 1   Water Solutions/Expansion/Sensors Outlet Transducer Maximum   145 psi Pressure Units PSI   Water Solutions/Expansion/Start Set Setpoint Ramp  5.0   Water Solutions/Expansion/Stage Number of External Pumps 1 Stage Speed  50 hZ  Jumper: +24 to CI_LI54 External Pump 1 No Fault +24 to CI_LI55 External Pump 2 No Fault +24 to CI_LI57      Auto enable   The Feedback Pressure(monitored under water Solution menu) must be lower than the Start Pressure(programmed in Start Set) when closing CI_LI57 and want the unit to start.
 
Wiring examples:
CLI57= auto enable or start
CLI58= fault reset

Transducer input
AI2= Analog input on the drive
AI52 and AI51= analog inputs on the water solutions card

Fault feedback inputs from aux pump overload relays
CLI54= for fault input for Aux pumpt 1
CLI55= for fault input for Aux pumpt 2
CLI56= for fault input for Aux pumpt 3

Aux pump outputs
CLO51= Aux output for pump 1
CLO52= Aux output for pump 2
CLO53= Aux output for pump 3

Status outputs from the WSC
CLO55= Run status
CLO56= Fault status

Jockey pump option
CLO56= Jockey or priming pump output


Water Solution Control Card User manual