    Is there an adjustment to reduce motor oscillation in the ATS48 softstart?

    Issue
    Is there an adjustment to reduce motor oscillation in the ATS48 softstart? 

    Product Line:
    ATS48  

    Environment
    All 

    Cause:
    Motor is making a imbalance noise during start and stop. 

    Resolution:
    Stator loss compensation 0 to 90%     default  50%
    Parameter active in acceleration phases (and deceleration phases if StY is set to -d-).
    In the event of torque oscillations, reduce this parameter gradually until the device is functioning correctly.
    Oscillations are most common if the soft starter is connected in motors with excessive slip.
     