    Error E7611 on the LXM32 drive

    Question:
    What is error E7611 on the LXM32 drive?

    Product Line:
    LXM32

    Resolution:
    Error E7611 means the resolver is inoperative due to one or more of the following reasons:
    - Very long resolver cable between the drive and the motor
    - Resolver is inoperative and motor needs to be repaired/replaced
    - Bad or no shield on resolver cable
    - High power cable running very close to the resolver cable