    Database Manager fails during database upgrade with "Could not upgrade MSDE Database: The transaction log for database 'ION_Data' is full due to 'ACTIVE_TRANSACTION'."

    Issue
    Customer is unable to upgrade a database using the Database Manager and received the following error:

    "Could not upgrade MSDE Database: The transaction log for database 'ION_Data' is full due to 'ACTIVE_TRANSACTION'."

    Product Line
    Power Monitoring Expert 8.x

    Environment
    Database Manager
    SQL Server Management Studio

    Cause
    The Autogrowth parameters are restricting the database from growing during the upgrade process.

    Resolution
    Verify the attached database has Autogrowth set to Unlimited.
     
    1. Open SQL Server Management Studio
    2. Connect to Server Instance
    3. In the Object Explorer, expand Databases
    4. Right-click on the database in question and select Properties
     
    1. Select the Files page
    2. Set the Primary filegroup to an Autogrowth/Maxsize of "By 10 percent, Unlimited"