    How do I remove the old files from the database server following an in-place upgrade of a distributed PME 8.2 Install?

    Issue
    After the completion of an in-place upgrade of a distributed Power Monitoring Expert 8.2 install, there are remaining files on the database server that would need to be removed

    Product Line
    Power Monitoring Expert 8.2

    Environment
    Power Monitoring Expert In-Place Upgrade of Distributed Database Server

    Cause
    Unlike prior version of Power Monitoring Expert, Power Monitoring Expert 8.2 no longer requires the installer to be run on the database server. he Application Server install type should be chosen, and the database server will be upgraded remotely. As such after an in-place upgrade, files are remaining on the database server which would need to be removed. 

    Resolution
    *Warning: Irreparable database damage can occur. This procedure should only be performed by
    users familiar with SQL Server Management Studio. Databases should be backed up prior to
    performing this procedure.*

    *Warning: Irreparable database damage can occur. This procedure should only be performed by users familiar with SQL Server Management Studio. Databases should be backed up prior to performing this procedure.*

    *Warning: Take backups of any files prior to modifying them. Ensure the backups are in a location that will not be overwritten (i.e. the Desktop).


    Once the system has been upgraded to PME 8.2, these old files can be removed by using 'Programs and Features' to uninstall them.

    This Step below needs to be performed on the PME 8.2 database server.
    What is important is to copy the attached custom broker file into the \Schneider Electric\Power Monitoring Expert\Uninst_PowerMonitoringExpert\BrokerFragements folder, over-writing the existing file. If this is not done, any SQL Agent jobs that reference Report Subscriptions will be removed, and the PME databases will be detached.

    See the attached document for additional information. The custom broker file is also attached.