    What is the CFi fault on an Altivar ATV630 and ATV930 Process drives?

    Issue:
    What is the CFi fault on an Altivar Process Drive?

    Product Line:
    Altivar Process Drive (ATV630, ATV930, ATV650, ATV950, ATV660, ATV960, ATV680, ATV980)

    Environment:
    All serial numbers for Altivar Process Drive

    Cause:
    N/A

    Resolution:
    Principle:
    Invalid Configuration Fault (CFi)
    If a configuration has been loaded which is inconsistent (invalid parameter value, the functions configured are incompatible, etc.), the drive state changes to CFI fault.
    This fault will be reset automatically once a consistent configuration has been loaded or as soon as a correct value is set for the parameters.

    Probable cause:
    The configuration loaded into the drive via serial link is invalid.

    Remedies:
    • Check the loaded configuration.
    • Load a valid configuration.



     