    Video: How to program an ATV320 for 3 wire control?

    Issue:
    Programming an Altivar ATV320 for 3 wire control

    Product Line:
    Altivar 320, ATV320

    Environment:
    All

    Cause:
    Programming, setup

    Resolution:



    From main menu,
    Enter on dial to go to CONF and enter.
    Go down to FULL and enter.
    Go down to I_0- and enter.
    Set TCC for 3C for 3 wire control.  This will require the enter key(dial) to be pressed for 3 seconds.
    In 3 wire control mode, DI1 is normally closed momentary stop and DI2 is normally open momentary start.
    If DI1 is not made the drive will display NST.