    Getting alarm A324 on LXM32 drive

    Issue:
    Getting alarm A324 on the LXM32 drive

    Product Line:
    Lexium 32
    LXM32

    Resolution:
    A324 is an error during the homing sequence of the LXM32
    Possible reasons are a bad insulation on the limit switch wire, EMC interference caused by running a power cable next to the limit switch wire, reference switch not enabled, low or no voltage on the reference or limit switches, multiple positive/negative/reference switches active