    What should the F601 current limit parameter be set to in the ATV212 drives?

    Issue:
    What should the F601 current limit parameter be set to in the ATV212 drives?

    Product Line:
    ATV212

    Environment:
    All

    Cause:
    What should the F601 current limit parameter be set to in the ATV212 drives?

    Resolution:
    The F601 Current limit parameter should be set to 110% of the Drives current rating. 
    Note: If you use a small size motor on a larger drive, you will need to adjust this setting to the motor FLA times 1.1.