    Getting E1100 error on the LXM32 servo drive

    Issue:
    Getting E1100 error on the LXM32 servo drive

    Product Line:
    LXM32

    Resolution:
    E1100 is a "parameter out of range" error. The parameter could be coming from a PLC or an HMI communication with the LXM32 drive and sending an out of range parameter like speed, acceleration, deceleration or position.