    Getting error E4102 on LXM32 drive.

    Issue:
    Getting E4102 on LXM32 drive

    Product Line:
    LXM32

    Resolution: E4102 = "power stage I2t".The drive creates a warning message (WarnLatched bit 30) and reduces to nominal current. There's no stop reaction in case of warnings.
    A warning is an error class 0 meaning there's no reaction in transition. If there are warnings (error class 0), the two dots to the right of the 7-segment display (2) flash.
    The parameters _WarnLatched and _SigLatched contain information on warnings and errors.
    It's also possible to define an output for a warning or error.