    What is error message 65344 from a Lexium integrated drive as read by the PLC?

    Error message 65344 converted to hex is FF40.
    This message is an indication that the drive received a message to make motion before the drive was in an enable state.
    The enable command must be sent prior to any commands related to motion or this error will be sent back as a response.