    What would cause the Altivar 312 drive to loose some of its settings when you switch from local to remote modes?

    Issue:
    What would cause the Altivar 312 drive to loose some of its parameters when you switch from local to remote mode?

    Product Line:
    Altivar 312

    Environment:
    All 

    Cause:
    The drive was set in local mode and they lost some of the parameter settings in the drive. 

    Resolution:
    The Altivar 312 drive is not designed to toggle between local and remote modes by holding the MOD button for 3 seconds without changing the Logic inputs back to factory default and resetting ref 1 and Cd1 channels in the drive back to default. 