    DUPLICATE: FA271880 What can cause a state of NST on an ATS48 Soft Start?

    Issue:
    The state is nSt
     
    Product Line:
    ATS48
     
    Environment:
    All models and serial numbers
     
    Cause:
    Forced to freewheel stop by a logic input or the serial link.

    Resolution:
    The nSt state is not a fault condition but is one that can be forced via a logic input or through the network via serial link.
     