    what are the OIDs for reading the LED status from Connexium Ethernet Switch TCSESM083F23F1 using SNMP Protocol in a MIB browser.

    The very first step is to install the correct MIB file in the MIB Browser.
    We need to install the two files in the MIB Browser.
    1.SchneiderTFE-V03-00.mib
    2.SchneiderElectricSwitches_V02_00.mib.
    Contact your local country Schneider Electric Customer Care Center to get this files.

    The LED status can for Power, Ring Manager, Standby, fault , Relay R1 and R2.
    The OID for them are as below.

    1. Power Supply P >> oid=".1.3.6.1.4.1.3833.1.1.14.1.1.35.3.1.0
    2. Fault >>  oid=".1.3.6.1.4.1.3833.1.1.14.1.1.35.3.4.0
    3. Ring Manager RM  >> oid=".1.3.6.1.4.1.3833.1.1.14.1.1.35.3.3.0"
    4. Standby >> oid=".1.3.6.1.4.1.3833.1.1.14.1.1.35.3.2.0"
    5. Relay R1 >> oid=".1.3.6.1.4.1.3833.1.1.14.1.1.35.3.5.0"
    5. Relay R2 >> oid=".1.3.6.1.4.1.3833.1.1.14.1.1.35.3.6.0"

     