    What will cause the ATV212 not to go into local mode when pressing the LOC/REM button?


    Issue: 
    What will cause the ATV212 not to go into local mode when pressing the LOC/REM button?

    Product Line:
    ALTIVAR 212, ALTIVAR 21

    Environment:

    All serial number

    Cause:
    When pressing the LOC/REM button the drive will not go to LOC mode.

    Resolution:
    Possible cause is parameter F732 is set to 1(LOC/REM button disable) for this reason set F732 to 0.   However, if the LOC/REM button is not disabled, then it is likely, the keypad is defective, the drive will need to be replaced