    Does Unity Pro run on Windows 2008 Server?

    Unity Pro v8 will run on Windows 2008 Server R2, standard edition, SP1.

    Windows 2008 Server allows two users to run Unity Pro via a Remote Desktop Connection.

    Only one user may be connected to the simulator at any given time.    If more than one user tries
    to connect to the Unity Pro simulator, an error message is returned. ("Can't start Comm. Server.  Port 502
    is already in use.")

    Each user running Unity Pro will be able to connect to any supported PLC.

    The type of license purchased will depend on how many users are running Unity Pro at the same time.
    The Remote Desktop sessions will not have to authorize Unity Pro. 
    Authorizing the installation running on the Windows 2008 server PC is sufficient.
     