    Will MPPT80 generate ground fault with floating array?

    Will MPPT80 generate ground fault with floating array?



     
    Issue:

    Installation may require floating array

    Environment:

    HV solar controller

    Resolution:
     
    On pg.2-8 of the installation guide, it states the MPPT80 can detect a ground fault when using ungrounded array :

     
    For ungrounded arrays, the unit detects the resistance between the

     
    array and ground, and it indicates a fault if the resistance is too low. The unit is

     
    configured at the factory for an ungrounded PV array connection. For both types

     
    of ground fault protection, if the unit determines that a ground fault has occurred,

     
    it will cease operating and will indicate a fault on the unit's display and over the

     
    Xantrex Xanbus? network (if used).

     



    Cause:

    Ground fault detection circuitry is active when using ungrounded array. Both polarities must be fused externally, a single disconnect (SquareD H361) may be utilized (see attached)