    Change Location

    Video: How is an ATS48 set up for standard basic programming?

    Issue:
    How is an ATS48 set up for standard basic programming?

    Product line:
    Altistart 48

    Environment:
    All models, all serial numbers

    Cause:
    Basic programming set up for the ATS48 soft starters.

    Resolution:
    SET menu:
    IN= FLA motor amps
    ACC= acceleration
    STY= type of stop (f=freewheel, d=ramp stop, b=intel braking)
    DEC= deceleration [only appears if Sty= d (ramp stop)]
    ILT=current limit 400%  or 4X your motor current is default value.

    DRC menu:
    CLP= Off (Torque Control).  This is important if the ACC/DEC times have to be followed exactly.

    Reference ATS48 programming manual S1A37491