    What does the BRF fault mean on the ATV71 drives?

    Issue:
    ATV71 drive is getting brake feedback fault (BRF)

    Environment:  
    All models, all serial numbers   

    Cause:
    The brake contact feedback is too one after the command to run is issued.

    Resolution:
    This is a brake feedback fault.  The brake feedback contact does not match the brake logic control.
    This function is available under 1.7 Brake logic control submenu.  
    If BRH b2 is set to 0 the reference is enabled at the end of the brake release time.  If BRH b2 is set to 1 then the reference is enabled when the feedback from brake contact enables a logic input and at the end of the brake release time.
    - check the feedback circuit and brake logic control.
    - check the mechanical state of the brake.


     