    Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

    Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
    Front Mounting; maximum of 1 block per contactor:

    N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
    --1-----------1---------LADN11-----------LA1DN11
    --1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
    --1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
    --2-----------0---------LADN20-----------LA1DN20
    --2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
    --2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
    --0-----------2---------LADN02-----------LA1DN02
    --2-----------2---------LADN22-----------LA1DN22
    --2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
    --2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
    --2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
    --3-----------1---------LADN31------------LA1DN31
    --3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
    --1-----------3---------LADN13------------LA1DN13
    --4-----------0---------LADN40------------LA1DN40
    --4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
    --0-----------4---------LADN04------------LA1DN04




    Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

    N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
    --1-----------0--------LADN10----------LA1DN10
    --0-----------1--------LADN01----------LA1DN01

    Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
    (*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

    N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
    --1-----------1--------LAD8N11----------LA8DN11
    --2-----------0--------LAD8N20----------LA8DN20
    --0-----------2--------LAD8N02----------N/A

    Footnotes:
    {1} EN50 012 Machine Tool Terminal Markings
    {2} (2) NO Sealed Dust Tight Contacts
    {3} Gold Flash Contacts
    {4} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
    {5} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
    {6} (2) NO Dust Tight Contacts & (2) NO Standard Contacts